Condor Engineering HN24-3.6-A+G Power Supply with 24V and 3.6A Current Simple Type: Power Supply
For Resellers and High Volume Orders:
Please request a quote to obtain preferred pricing.
Features
- All electrolytic caps rated at 105°C
- Burn-in with cycling
- Capacitors have highest CV & ripple current ratings
- Commercial UL/CSA TUV/IEC approved—models to UL/CSA 60950; EN/IEC60950-1
- Exceed FCC and CISPR22, Class B conducted emissions
- Industry standard packages
- Medical Approved to UL2601-1/60601-1, IEC60601-1 and CSA601.1
- Medical leakage 10 µA
- MTBF 200,000+ hours per MIL-HDBK-217D (most units)
- Transformer insulation meets Class F (155°C)
- World-wide ac input ranges and safety standards
Specifications
- Ac Input: 100, 120 and 240 Vac: +10%, -13%; 215 Vac: +12%, -11%; 47 to 63Hz. Tolerance for 230 Vac operation is +15%, -10%. Derate output current 10% for 50 Hz operation
- Dc Output: Adjustment range ±5% minimum
- Efficiency: 5 V units: 45%; 12 and 15 V units: 55%; 20 and 24 V units: 60%
- Line Regulation: ±0.05% for a 10% change
- Load Regulation: ± 0.05% for a 50% load change
- Logic Inhibit and Current-Share: F & G models
- Medical Stock and Vibration: Per Mil-Std-810D, Method 514.3, Category 1, Procedure 1; Per Mil-Std-810D, Method 516.3, Procedure III
- Output Ripple: 3 mV +0.05% of output voltage, peak to peak maximum. All “3-terminal regulator” outputs: 3 mV +0.2% peak to peak maximum
- Overvoltage Protection: Built-in on all 5 V models, set at 6.2 V ±0.4 V. Other models use optional over-voltage protection
- Remote Sensing: Provided on all models; open sense lead protection built-in (except HA & HTAA series)
- Short Circuit Protection: Automatic current limit/foldback
- Stability: ±0.05% for 24 hours after warmup
- Storage: -40 to +85°C
- Temperature Coefficient: ±0.01%/°C maximum
- Temperature Rating: 0 to 50°C full rated, derated linearly to 40% at 70°C
- Transient Response: <50 microseconds for 50% load change
Applications
- None Available
Aliases